Rinnai EX38DTWP Direct Vent Wall Furnace, 36,500 BTU, Propane, White

$2,642.22 Regular Price
$1,973.74Sale Price

Buy more, save more: buy 4+, extra 15% off · Buy more, save more: buy 3, extra 10% off

Quantity

The Rinnai EX38DTWP is an EX DT Series ductless wall furnace that burns liquid propane and vents directly outdoors through a concentric pipe. It modulates between 13,200 and 36,500 BTU/h and comes in a white cabinet, suited to zone or supplemental heating or to working alongside an existing heating system.

Modulating control matches burner output to the heat the room calls for, which saves energy. A programmable thermostat reads in Fahrenheit or Celsius and responds to temperature shifts under 1 degree. The control panel can be locked against unintended operation, especially by children, and the cabinet surface stays cool to the touch while running.

Ignition is direct electronic, power is 120 V AC at 60 Hz, and gas enters through a 1/2 in. FNPT connection. Built-in self-diagnostics help a technician pinpoint faults during service. The cabinet measures 26.40 in. high, 36.63 in. wide and 12.60 in. deep and weighs 108 lb. Heated area depends on climate and where the unit sits in the home, and professional installation is recommended.

Highlights

  • Modulating input from 13,200 to 36,500 BTU/h on liquid propane

  • Ductless direct vent design with concentric venting

  • Programmable thermostat in °F or °C senses changes under 1 degree

  • Lockable control panel and cool-to-the-touch cabinet

  • Onboard self-diagnostics simplify troubleshooting

  • White finish, 120 V AC, 1/2 in. FNPT gas connection

Specifications

Brand

Rinnai

Model

EX38DTWP

Input range

13,200-36,500 BTU/h

Max input

36,500 BTU/h

Fuel

Liquid propane

Venting

Direct vent, concentric

Ignition

Direct electronic

Voltage

120 V AC, 60 Hz

Gas connection

1/2 in. FNPT

Finish

White

Height

26.40 in.

Width

36.63 in.

Depth

12.60 in.

Weight

108 lb

Good to know

  • Gas-fired appliance: it must be installed, vented and commissioned by a qualified installer in line with local codes and the manufacturer's installation manual.